Numerical Investigation of Double Corrugated Steel Plate Shear Walls
DOI:
https://doi.org/10.32732/jcec.2021.10.1.44Keywords:
Steel plate shear wall; Corrugated plate; Double infill plate; Cyclic behavior; Numerical simulation.Abstract
Recently, corrugated steel plate shear walls have been shown to be an efficient lateral force resisting system for building structures. Corrugated plates have higher out-of-plane stiffness and improved buckling stability in comparison with flat plates which result in improved hysteretic behavior. However, the thickness of the corrugated plates may be limited due to the cold-form process restrictions. This paper investigates the cyclic performance of double corrugated steel plate shear walls. One-story single-bay specimen was designed and modelled and parametric studies were performed. The parametric study considered the orientation of corrugated plates (horizontal or vertical), disconnection of infill plates from columns, disconnection of infill plates from each other, infill plate thickness and infill plate aspect ratio on cyclic performance of double corrugated steel plate shear walls. The present study results show that proper selection of the aforementioned parameters can lead to a desirable cyclic performance. In the end, a recommendation for calculating initial stiffness and ultimate strength of double corrugated steel plate shear walls is given.
Downloads
Published
Issue
Section
License
Copyright (c) 2021 S.M. Ghodratian-Kashan, S. Maleki

This work is licensed under a Creative Commons Attribution 4.0 International License.